- Freq. Range : 10MHz to 40GHz in coax using the Giga-tronics 80300 Series power sensors and 80500 Series Bridges.
- Power Range : -70 to +30, see power sensor specifications

Measures active and passive components with power meter accuracy from 10 MHz to 40 GHz. AC and DC detection is available with equal accuracy on the 3 inputs and standard, high-power, true RMS, low VSWR and triggerable pulse power sensors are available.

  • Sensor frequency range from 0.01 to 18, 20, 26.5, or 40 GHz
  • Dynamic Range: 90 dBm; -70 to +20 dBm CW; -20 to +20 dBm Pulse
  • Linearity of +/- 0.02 dB (0.5%) over any 20 dB span
  • Linearity of +/- 0.04 dB (1%) over the entire 90 dB span

Warranty

1³â

»çÀ̹ö°ßÀû´ã±â

8003


¸ðµ¨

±¸¼º / ¼³¸í

»çÀ̹ö°ßÀû´ã±â

Opt. 01

Rack Mount Kit

8003 (Opt. 01)

Opt. 02

RGB Interface

8003 (Opt. 02)

21044

18GHz Attenuator Calibration Kit

21044

21049

26.5GHz Attenuator Calibration Kit

21049

20791

Extra Operating Manual for 8003

20791

20791-001

Extra Service Manual for 8003

20791-001

20641

PC Board Extender Kit

20641

21003

BNC/GPIB Cable kit (was Opt. 03)

21003

EWS20

2 Year Extended Warranty

¹®ÀÇ

 

Per Unit Production Test Data

¹®ÀÇ

 

Per Unit Equipment Traceability List

¹®ÀÇ


Power Sensor & Bridge Data Sheet

Triggerable Pulse Sensors

»çÀ̹ö°ßÀû´ã±â

80340A

Triggerable Pulse Sensor  +20 to -20 dBm; 50 MHz to 18 GHz, N(m)

80340A

80343A

Triggerable Pulse Sensor  +20 to -20 dBm; 50 MHz to 26.5 GHz, K(m)

80343A

80344A

Triggerable Pulse Sensor  +20 to -20 dBm; 50 MHz to 40 GHz, K(m)

80344A

21067-001

Trigger/Detector Cable for 8034XA Series 20. Meters (6 Feet)

21067-001

21025

Extra Operating & Maintenance Manual for Power Sensor 8034XA Series

21025

 Universal CW Power Sensors

»çÀ̹ö°ßÀû´ã±â

80301A

Standard Power Sensor +20 to -70 dBm; 10 MHz to18.0 GHz, N (m)

80301A

80302A

Standard Power Sensor +20 to -70 dBm; 10 MHz to 18.0 GHz, APC-7

80302A

80303A

Standard Power Sensor +20 to -70 dBm; 10 MHz to 26.5 GHz, K (m)

80303A

80304A

Standard Power Sensor 0 to -70 dBm; 10 MHz to 40.0 GHz, K(m)

80304A

80310A

Low VSWR Power Sensor +26 to -64 dBm; 10 MHz to 18.0 GHz, K(m)

80310A

80313A

Low VSWR Power Sensor +26 to -64 dBm; 10 MHz to 26.5 GHz, K(m)

80313A

80314A

Low VSWR Power Sensor +6 to -64 dBm; 10 MHz to 40.0 GHz, K(m)

80314A

80320A

High Power (1W) Power Sensor +30 to -60 dBm; 10 MHz to 18.0 GHz, K(m)

80320A

80323A

High Power (1W) Power Sensor +30 to -60 dBm; 10 MHz to 26.5 GHz, K(m)

80323A

80324A

High Power (1W) Power Sensor +10 to -60 dBm; 10 MHz to 40.0 GHz, K(m)

80324A

80321A

High Power (5W) Power Sensor +37 to -50 dBm;10 MHz to 18.0 GHz, N(m)

80321A

80322A

High Power (25W) Power Sensor +44 to -40 dBm;10 MHz to18.0 GHz,N(m)

80322A

80325A

High Power (50W) Power Sensor +47 to -40 dBm;10 MHz to 18.0 GHz,N(m)

80325A

Warranty

1³â

Opt. 10

100KHz to 18GHz Operation (for 18GHz Sensors Only)

CW (Opt.10)

 Universal Power Measurement Accessories

»çÀ̹ö°ßÀû´ã±â

20954-001

Power Sensor Cable, 1.5 Meters (5 feet)

20954-001

20954-002

Power Sensor Cable, 3.0 Meters (10 feet)

20954-002

20954-003

Power Sensor Cable, 7.5 Meters (25 feet)

20954-003

20954-004

Power Sensor Cable, 15.0 Meters (50 feet)

20954-004

21564-001

Bulkhead Cable Assembly, Right Angle, 1.0 Meters (3 feet)

21564-001

21564-002

Bulkhead Cable Assembly, Right Angle, 4.5 Meters (15 feet)

21564-002

JRXC-00400

Microwave Adapter, N(m) to SMA(f)

JRXC-00400

JRXC-00200

Microwave Adapter, APC-7 to N(m)

JRXC-00200

 Power Sensors °øÅë Option

»çÀ̹ö°ßÀû´ã±â

EWS20

2 Year Extended Warranty

¹®ÀÇ

 

Per Unit Production Test Data

¹®ÀÇ

 

Per Unit Equipment Traceability List

¹®ÀÇ

 Bridge

»çÀ̹ö°ßÀû´ã±â

80501

Directional Bridge (10MHz to 18GHz), N

80501

80502

Directional Bridge (10MHz to 18GHz), APC-7

80502

80503

Directional Bridge (10MHz to 26.5GHz), WSMA

80503

80504

Directional Bridge (10MHz to 40GHz), K

80504

20779A

Bridge Adapter

20779A

EWS20

2 Year Extended Warranty

¹®ÀÇ

 

Per Unit Production Test Data

¹®ÀÇ

 

Per Unit Equipment Traceability List (includes NIST traceability chart)

¹®ÀÇ


  À̸§
  ¿¬¶ôó
  E-mail
  Áö¿ª    ¿¹) °æ±âµµ ¼º³²
  ¹®Àdz»¿ë