광 손실 테스트 세트, 광원/광 파워미터 CMA5

The CMA5 series (Optical Light Source / Optical Power Meter) supports measurement of optical power and loss of wavelengths used by MM and SM fiber installations.
- • Supports MM model (850nm / 1300nm), SM model (1310nm / 1550nm)
- • Lightweight at only 250g
- • Measures up to +23dBm optical power (Power Meter)
제품 사양
Light Source | 5L83 | 5L35 |
---|---|---|
Emitter Type | LD | |
Wavelength | 850/1300 ±20 nm | 1310/1550 ±20 nm |
Output Power | –7 dBm | |
Source Line Width | <5 nm | |
Modulation Output | CW, 270 Hz, 1 kHz, 2 kHz | |
Connector Type | FC, ST, SC | |
Input Power | 9 V alkaline battery | |
Dimensions | 75 (W) × 145 (H) × 25 (D) mm | |
Mass | 250 g | |
Warranty | 3 years |
Optical Power Meter | 5P100 | 5P100C |
---|---|---|
Connector Type | FC, SC, ST | |
Fiber Type | MM, SM | |
Detector Type | InGaAs-PD | |
Calibrated Wavelength | 850/1300/1310/1490/1550/1625 nm | |
Measurement Range | –60 to +10 dBm | –50 to +23 dBm |
Display Resolution | 0.01 dB | |
Modulation Detection | 2 kHz modulation | |
Input Power | 9 V alkaline battery | |
Dimensions | 75 (W) × 145 (H) × 25 (D) mm | |
Mass | 250 g | |
Warranty | 3 years |
Optical Power Meter | 5LT35 | 5LT35C | 5LT83 |
---|---|---|---|
Light Source Port | |||
Fiber Type | SM, PC | MM, PC | |
Emitter Type | LD | ||
Wavelength | 1310 nm/1550 nm ±20 nm | 1310 nm/1550 nm ±20 nm | |
Output Power | ≥ –7 dBm | ||
Source Line Width | ≤ 5 nm | ||
Modulation Output | CW, 270 Hz, 1 kHz, 2 kHz | ||
Connector Type | FC/PC, SC/PC, ST/PC | ||
Optical Power Meter Port | |||
Fiber Type | SM, MM | ||
Detector Type | InGaAs | ||
Calibrated Wavelength | 850, 1300, 1310, 1490, 1550, 1625 nm | ||
Measurement Range | –60 to +5 dBm | –40 to +23 dBm | –60 to +5 dBm |
Display Resolution | 0.01 dB | ||
Connector Type | FC, SC, ST | ||
General Specifications | |||
Input Power | 9 V alkaline battery | ||
Dimensions | 75 (W) × 145 (H) × 25 (D) mm | ||
Mass | 300 g | ||
Warranty | 3 years |
옵션 & 액세서리
Options | |
---|---|
5LT35-YY | Optical Loss Tester 1310 nm/1550 nm (Standard Power Meter) |
5LT35C-YY | Optical Loss Tester 1310 nm/1550 nm (CATV Power Meter) |
5LT83-YY | Optical Loss Tester 850 nm/1300 nm (Standard Power Meter) |
5L35-YY | Light Source: 1310 nm/1550 nm (Dual wavelength for SM fiber) |
5L83-YY | Light Source: 850 nm/1300 nm (Four wavelength for MM fiber) |
5P100-YY | Optical Power Meter (Standard): –60 to +10 dBm |
5P100C-YY | Optical Power Meter (CATV): –50 to +23 dBm |
Standard Accessories | |
---|---|
CMA5 Manual | 1 pc |
Rubber Protective Cover | 1 pc |
9 V Alkaline Battery | 1 pc |
Standard Accessories | |
---|---|
GN-3HH-CASE | Hard Case (for two CMA5 series) |
CMA5-POUCH-A | Carrying Pouch/Shoulder Strap |
CMA5-BAT | 9 V Alkaline Battery |
Z1525A | AC Adapter (CMA5) |
CMA5-AD-LS-FC | FC Connector Adapter (Light Source Port) |
CMA5-AD-LS-SC | SC Connector Adapter (Light Source Port) |
CMA5-AD-LS-ST | ST Connector Adapter (Light Source Port) |
CMA5-AD-LS-ALL3 | Connector Adapter (FC, SC and ST) |
CMA5-AD-PM-FC | FC Connector Adapter (Power Meter Port) |
CMA5-AD-PM-SC | SC Connector Adapter (Power Meter Port) |
CMA5-AD-PM-ST | ST Connector Adapter (Power Meter Port) |
CMA5-AD-PM-ALL3 | Connector Adapter (FC, SC and ST) |
J1530A | SC Plug-in Converter (UPC(P)-APC(J)) |
J1532A | FC Plug-in Converter (UPC(P)-APC(J)) |
J1534A | LC-SC Plug-in Converter (for SM, SC(P)-LC(J)) |
J1535A | LC-SC Plug-in Converter (for MM, SC(P)-LC(J)) |
자료실
제 목 | 파일 다운로드 |
---|---|
등록된 자료가 없습니다. |