Model
|
K3003D
|
K3005D
|
K6003D
|
|
Max. Ouput power
|
90W x 2 / 180W
|
150W x 2 / 300W
|
180W x 2 / 360W
|
|
DC Output
|
Voltage
|
30V x 2
|
30V x 2
|
60V x 2
|
|
Current
|
3A x 2
|
5A x 2
|
3A x 2
|
|
Programming Accuracy ±(% of output + offset)
|
|
Voltage
|
P1 : 0.03%+15mV P2 : 0.10%+25mV
|
P1 : 0.03%+15mV P2 : 0.10%+25mV
|
P1 : 0.05%+20mV P2 : 0.10%+25mV
|
|
Current
|
P1 : 0.1%+5mV P2 : 0.1%+10mV
|
P1 : 0.1%+5mV P2 : 0.1%+10mV
|
P1 : 0.1%+5mV P2 : 0.1%+10mV
|
|
Readback Accuracy ±(% of output + offset)
|
|
Voltage
|
P1 : 0.03%+10mV P2 : 0.10%+20mV
|
P1 : 0.03%+10mV P2 : 0.10%+20mV
|
P1 : 0.05%+15mV P2 : 0.10%+20mV
|
|
Current
|
P1 : 0.1%+3mV P2 : 0.1%+7mV
|
P1 : 0.1%+3mV P2 : 0.1%+7mV
|
P1 : 0.1%+3mV P2 : 0.1%+7mV
|
|
Load Regulation ±(% of output + offset)
|
|
Voltage
|
0.01%+2mV
|
0.01%+2mV
|
0.01%+2mV
|
|
Current
|
0.01%+1mA
|
0.01%+1mA
|
0.01%+1mA
|
|
Line Regulation ±(% of output + offset)
|
|
Voltage
|
0.01%+2mV
|
0.01%+2mV
|
0.01%+2mV
|
|
Current
|
0.01%+1mA
|
0.01%+1mA
|
0.01%+1mA
|
|
Ripple & Noise (20Hz to 20MHz)
|
|
Normal Mode Voltage
|
P1 : 0.5mVrms, 3mVpp P2 : 0.5mVrms, 8mVpp
|
P1 : 0.5mVrms, 3mVpp P2 : 0.5mVrms, 8mVpp
|
P1 : 0.5mVrms, 4mVpp P2 : 0.5mVrms, 8mVpp
|
|
Normal Mode Current
|
1mArms
|
1mArms
|
1mArms
|
|
Resolution
|
|
Program
|
1mV/1mA
|
1mV/1mA
|
10mV/1mA
|
|
Readback
|
1mV/1mA
|
1mV/1mA
|
10mV/1mA
|
|
Meter
|
1mV/1mA
|
1mV/1mA
|
10mV/1mA
|
|
Voltage Programming Speed
|
|
Up - Full Load No Load
|
12msec 12msec
|
12msec 12msec
|
16msec 16msec
|
|
Down - Full Load No Load
|
15msec 110msec
|
15msec 110msec
|
20msec 250msec
|
|
Transient Response
|
Less than 50us for output recover to within 15mV following a change in current output from full load to half load
|
|
Command Processing Time
|
50msec < 100msec
|
|
»çÀ̹ö°ßÀû´ã±â
|

|

|

|
|
Model
|
AK3003D
|
AK3005D
|
AK6003D
|
|
Max. Ouput power
|
90W x 2 / 180W
|
150W x 2 / 300W
|
180W x 2 / 360W
|
|
DC Output
|
Voltage
|
30V x 2
|
30V x 2
|
60V x 2
|
|
Current
|
3A x 2
|
5A x 2
|
3A x 2
|
|
Programming Accuracy ±(% of output + offset)
|
|
Voltage
|
P1 : 0.03%+15mV P2 : 0.10%+25mV
|
P1 : 0.03%+15mV P2 : 0.10%+25mV
|
P1 : 0.05%+20mV P2 : 0.10%+25mV
|
|
Current
|
P1 : 0.1%+5mV P2 : 0.1%+10mV
|
P1 : 0.1%+5mV P2 : 0.1%+10mV
|
P1 : 0.1%+5mV P2 : 0.1%+10mV
|
|
Readback Accuracy ±(% of output + offset)
|
|
Voltage
|
P1 : 0.03%+10mV P2 : 0.10%+20mV
|
P1 : 0.03%+10mV P2 : 0.10%+20mV
|
P1 : 0.05%+15mV P2 : 0.10%+20mV
|
|
Current
|
P1 : 0.1%+3mV P2 : 0.1%+7mV
|
P1 : 0.1%+3mV P2 : 0.1%+7mV
|
P1 : 0.1%+3mV P2 : 0.1%+7mV
|
|
Load Regulation ±(% of output + offset)
|
|
Voltage
|
0.01%+2mV
|
0.01%+2mV
|
0.01%+2mV
|
|
Current
|
0.01%+1mA
|
0.01%+1mA
|
0.01%+1mA
|
|
Line Regulation ±(% of output + offset)
|
|
Voltage
|
0.01%+2mV
|
0.01%+2mV
|
0.01%+2mV
|
|
Current
|
0.01%+1mA
|
0.01%+1mA
|
0.01%+1mA
|
|
Ripple & Noise (20Hz to 20MHz)
|
|
Normal Mode Voltage
|
P1 : 0.5mVrms, 3mVpp P2 : 0.5mVrms, 8mVpp
|
P1 : 0.5mVrms, 3mVpp P2 : 0.5mVrms, 8mVpp
|
P1 : 0.5mVrms, 4mVpp P2 : 0.5mVrms, 8mVpp
|
|
Normal Mode Current
|
1mArms
|
1mArms
|
1mArms
|
|
Resolution
|
|
Program
|
1mV/1mA
|
1mV/1mA
|
10mV/1mA
|
|
Meter
|
1mV/1mA
|
1mV/1mA
|
10mV/1mA
|
|
Voltage Programming Speed
|
|
Up - Full Load No Load
|
12msec 12msec
|
12msec 12msec
|
16msec 16msec
|
|
Down - Full Load No Load
|
15msec 110msec
|
15msec 110msec
|
20msec 250msec
|
|
Transient Response
|
Less than 50us for output recover to within 15mV following a change in current output from full load to half load
|
|